RFC 2544 Tests
RFC 2544 is a standard for performing network/device characterization tests.
- Objective: Run RFC 2544 based 4 network characterization tests on Puma and will be performed using Xena chassis.
- Setup: P2P, Multi-Hop
- Frame Sizes to be used: 64, 128, 256, 512, 1024, 1280, 1518
All Tests
PUMA_RF_RFC1
Throughput test
Description: This test determines the throughput of a DUT.
Procedure:
- Bring up the P2P link.
- Connect the two nodes to the ports on Xena chassis.
- Run throughput test for the specified frame sizes.
Pass/Fail Criteria:
- Xena must be able to deliver the throughput results successfully.
PUMA_RF_RFC2
Latency and Jitter test
Description: This test finds the latency and Jitter of a DUT.
Procedure:
- Bring up the P2P link.
- Connect the two nodes to the ports on Xena chassis.
- Run latency and jitter test for the specified frame sizes.
Pass/Fail Criteria:
- Xena must be able to deliver the latency and Jitter results successfully.
PUMA_RF_RFC3
Frame loss rate test
Description: This test determines the frame loss rate of a DUT.
Procedure:
- Bring up the P2P link.
- Connect the two nodes to the ports on Xena chassis.
- Run frame loss rate test for the specified frame sizes.
Pass/Fail Criteria:
- Xena must be able to deliver the frame loss rate results successfully.
PUMA_RF_RFC4
Back-to-back test
Description: This test characterizes the ability of a DUT to process back-to-back frames at various rates.
Procedure:
- Bring up the P2P link.
- Connect the two nodes to the ports on Xena chassis.
- Run frame loss rate test for the specified frame sizes.
Pass/Fail Criteria:
- Xena must be able to deliver the back-to-back results successfully.
PUMA_RF_POP_SPANOUT
Description: To test Maximum aggregated throughput at the POP site when all four sectors of the site have a terra link.
Test Setup: 4 sector POP site connected to 4 primaries
Procedure:
- Ignite topology to bring up all four terra links each of the POP sectors.
- Start 4 flows of bidirectional UDP traffic from primary on POP node to each of the four sites for 900s.
- Repeat above step for TCP traffic.
- Measure aggregated throughput at POP node.
Pass/Fail Criteria:
- Should achieve an aggregated throughput of 4*(4G) bidirectional traffic at the POP nodes from the 4 traffic flows.
PUMA_RF_3-SECTOR
Description: To test Maximum aggregated throughput at the POP site when 3 sectors of the site have RF terra link.
Test Setup: RF POP site connected to 3 primaries
Procedure:
- Bring up 3 terra links of the POP sectors.
- Start 3 flows of bidirectional UDP traffic from primary on POP node to each of the three sites for 900s.
- Repeat above step for TCP traffic.
- Measure aggregated throughput at POP node.
Pass/Fail Criteria:
- Should achieve an aggregated throughput of 3*(1G) bidirectional traffic at the POP nodes from the 3 traffic flows.