E2E Controller Tests

Basic Tests

PUMA_RF_E2E-REG-1 RF Software Upgrade/Downgrade Test

Description: This test is to check that the network successfully does upgrade and downgrade and comes back online after software upgrade/downgrade.

Test Setup: Fig-of-8

Procedure:

  • Upgrade both primary and backup controller to new version
  • Downgrade to a previous stable code
  • Download code and upgrade whole network to new version
  • Measure time taken for prepare and commit phase

Pass/Fail Criteria:

  • All nodes should be able to download new code and run upgrade and successful come back online within given timeout

PUMA_RF_E2E-REG-2 Power Outage network recovery Test

Description: This test checks that after power outage the network ignites by itself.

Test Setup: Fig-of-8

Procedure:

  • Check network is ignited
  • Power cycle all nodes by using the PDUs on the poles remotely
  • Check network recovery
  • Repeat 10 times

Pass/Fail Criteria:

  • Validate all links and nodes come back online after power failure within given timeout

PUMA_RF_E2E-REG-3 POP Fiber cut Test (multi-POP)

Description: This test is to check that if connection to 1 POP node is terminated then the network will recover and reroute through the other POP nodes.

Test Setup: Fig-of-8

Procedure:

  • Check network is ignited
  • Switch off fiber port on ubiquiti switch connecting to one of the POP nodes

Pass/Fail Criteria:

  • Network should recover and reroute through other POP node
  • All links and nodes should be online in the topology

PUMA_RF_E2E-REG-4 POP Fiber cut Test (single-POP)

Description: This test checks network ignition functionality on a standard figure of 8 topology with single POP. Post network ignition, cutting the fiber from switch to POP and checking whether the network is down

Test Setup: Fig-of-8

Procedure:

  • Ignite the topology (single POP)
  • switch off fiber port on ubiquiti switch connecting to POP
  • switch on the fiber port on ubiquiti switch connecting to POP

Pass/Fail Criteria:

  • Network goes down after the fiber cut to POP happens.
  • After switching on the fiber connectivity to POP the network should be up and active.

PUMA_RF_E2E-1 Network Ignition Tests

Description: This test checks network ignition functionality on a standard figure of 8 topology. Post network ignition, each node in the topology is pinged from the controller to validate connectivity.

Test Setup: Fig-of-8

Procedure:

  • Bring up the network using x86 controller. To bring up a network,
    • Existing topology file can be copied to the controller and controller can be started using systemctl services.
  • After ignition of the network, ping from E2E to all nodes.
  • Check whether the network is up and active.
  • Check the ignition state of the controller using REST API. (/api/getIgnitionState)

Pass/Fail Criteria:

  • All links remain up and reachable from controller to all nodes and ping session remains unaffected.
  • Ping from E2E to all nodes should succeed.
  • Ignition time of the fig-of-8 network must be less than 5 min.

PUMA_RF_E2E-2 POP node power cycle test

Description: This test checks network ignition functionality on a standard figure of 8 topology. In this test, POP node comes back online after the power cycle and all links and nodes in the network are expected to recover.

Test Setup: Fig-of-8

Procedure:

  • Bring up the network using x86 controller with all the nodes.
  • Check whether the network is up and active.
  • Power cycle the pop_node in the topology (/api/rebootNode)
  • While pop_node is down, send traffic through POP node to all other nodes.
  • While sending traffic when POP node is down, throughput drops to zero.
  • After POP is up, throughput should raise.
  • Validate all wireless links are up and routable from the pop_node.

Pass/Fail Criteria:

  • Throughput of zero is observed while traffic is pushed from controller when POP is down.
  • Raising in the throughput value should happen while traffic is pushed from controller after POP is up.

PUMA_RF_E2E-3 Node failure during network ignition

Description: This test checks network ignition functionality on a standard figure of 8 topology. However, during the process of network ignition, some node are rebooted and check whether E2E is bringing up the network.

Test Setup: Fig-of-8

Procedure:

  • Ignite the network using x86 controller.
  • During network ignition, randomly pick a DN and reboot it.
  • Wait for the last DN to boot up (ping sectors through OOB).
  • Check to see all the links in the topology came up successfully.
  • Ping each node and see for connectivity.
  • Iterate node bootup for 5 times and check for connectivity

Pass/Fail Criteria:

  • All the links in the testbed successfully come up.

Description: This test checks network ignition functionality on a standard figure of 8 topology. During the process of network ignition, any of the previously ignited links goes down.

Test Setup: Fig-of-8

Procedure:

  1. Ignite the network using x86 controller.
  2. During network ignition, bring down an ignited link (tg link down/attenuator) using /api/setLinkStatus.
  3. Check to see all the links in the topology came up successfully after 60 sec (re-ignition time?).
  4. Ping all nodes and see for connectivity.

Pass/Fail Criteria:

  1. All the links in the testbed successfully come up.
  2. No wireless link takes more than 5 attempts to come up.

PUMA_RF_E2E-5 Repeated link failure(s) post network ignition

Description: This test checks network ignition functionality on a standard figure of 8 topology. During the process of network ignition, any of the previously ignited links go down repeatedly.

Test Setup: Fig-of-8

Procedure:

  1. Ignite the network and ping across each wireless link to validate connectivity.
  2. Pick any wireless links at random and take them down (tg link down) using /api/setLinkStatus.
  3. Wait (X*60) seconds for E2E controller to re-ignite links.
    • X = { 1, 2, 3, 4 }
  4. Ping across each wireless link (can use lo interface) to validate connectivity. (/api/startPing)
  5. Ping to each end of each wireless link to validate they are reachable via E2E controller and pop_node.
  6. Repeat the above steps 20 times.

Pass/Fail Criteria:

  1. Network check to see all the links in the topology came up successfully.
  2. E2E controller is able to re-ignite all links taken down within (X*60) seconds and they are pingable across local DN sector interfaces and reachable via the pop_node.

PUMA_RF_E2E-6 Repeated node failure(s) post network ignition

Description: This test checks network ignition functionality on a standard figure of 8 topology. During the process of network ignition, any of the previously ignited node go down repeatedly.

Test Setup: Fig-of-8

Procedure:

  • Ignite the network topology using x86 controller.
  • Ping across each wireless link (using link local addresses) to validate connectivity. (/api/startPing)
  • Pick up to X DN sectors at random and take them down (via reboot). (/api/rebootNode)
  • Wait (X*60) seconds for DNs to boot up within 60 seconds.
    • X = { 1, 2, 3, 4 }
  • Wait (X*60) seconds for E2E controller to re-ignite all DN sectors.
    • X = { 1, 2, 3, 4 }
  • Ping each sector from pop_node.
  • Repeat the above steps 10 times.

Pass/Fail Criteria:

  • Check to see all the links in the topology came up successfully.
  • E2E controller is able to re-ignite all DN sectors taken down within (X*60) seconds of them coming up and they are reachable via the pop_node.

PUMA_RF_E2E-7 Network outage to controller

Description: This test checks whether network is unperturbed by temporary loss of connectivity to E2E in figure of 8 topology.

Test Setup: Fig-of-8

Procedure:

  1. Ignite the network using x86 controller.
  2. Check network state to verify if all links are enabled and nodes are reachable(recheck network state).
  3. Take down controller network interface for 300 sec (but do not shut down the controller)
    • ifconfig ens160 down; sleep 300; ifconfig ens160 up
  4. In parallel, Ping between nodes while the controller is not reachable from them.
  5. Recheck network state again after 300sec while pinging across all the nodes

Pass/Fail Criteria:

  1. All paths are up and operational after restoration of connection to E2E
  2. Ping between all nodes/Paths should have 0% packet loss.

PUMA_RF_E2E-8 Controller crash test

Description: This test checks whether network is unperturbed by killing E2E in figure of 8 topology.

Test Setup: Fig-of-8

Procedure:

  1. Ignite the network using x86 controller.
  2. Check network state to verify if all links are enabled and nodes are reachable(recheck network state).
  3. Start iterate (count: 5)
    1. Start ping from from POP to any node and in parallel, kill E2E controller on the controller x86. Ping across each wireless link (using lo address) to validate L3 wireless connectivity. (killall e2e_controller)
    2. Bring down any link in the network while E2E is down. (tg link down)
    3. Re-spawn E2E controller on x86 and wait 60 seconds
  4. End iterate

Pass/Fail Criteria:

  1. All links remain up and reachable via POP node after re-spawning E2E controller.
  2. Ping session remains unaffected during the duration of controller kill/restart.

PUMA_RF_E2E-9 Software Upgrade/Downgrade test using BitTorrent

Description: The purpose of this test is to validate the BitTorrent SW upgrade process at the network level, for a figure of "8" network topology.

Test Setup: Fig-of-8

Upgrade steps:

  • Add the image binary file manually to the /data/images directory and restart controller.
  • The image file name has to be in the format <NAME>.bin where NAME is the MD5 string of the binary image. The MD5 string is part of the binary file header.
  • During ignition of controller, global addressable ipv6 interface on the controller is set on the flag as bt_tracker_ipv6_global_addressable_ifname "interfacename".

APIs used:

/api/sendUpgradeRequest
/api/getUpgradeState
/api/getUpgradeCommitPlan
/api/addUpgradeImage
/api/delUpgradeImage
/api/listUpgradeImages
/api/abortUpgrade

Procedure:

  1. Bring up TG network using E2E controller on a X86 machine. Set the flag bt_tracker_ipv6_global_addressable_ifname "interfacename" during ignition.
  2. Start the tracker in the port 6969 by running command:
    • tg upgrade torrent start_tracker -g ens160 -p 6969
  3. Kill the running e2e_controller and then start again.
  4. Run the prepare torrent command"
    • tg upgrade network prepare_torrent -m 'magnet url' --md5 'md5 of bin'
    • Magnet url and md5 can be obtained by running command on the controller:
      • tg upgrade torrent list_images
  5. Run a script (/data/stop_minion.sh) on all nodes to emulate random nodes down by restarting e2e_minion at random time interval.
  6. Delay for 300 seconds
  7. Check if all nodes are prepared (excluding the ones which were down). Optimization: All nodes should be prepared.
  8. Run command to prepare all nodes again.
  9. Check if all nodes are prepared (including the ones which were down).
  10. Commit upgrade:
    • tg upgrade network commit
  11. Verify if upgrade is successful.
  12. Follow the steps from 2 to 10 for downgrade with new image.
  13. Verify if downgrade is successful.

Pass/Fail Criteria:

  1. Network comes up with new software for all nodes.
  2. Optimization: Nodes are not reflashed a 2nd time with same software version.

Description: Validate controller addition and deletion of nodes/links to topology from the TG CLI.

Test Setup: Fig-of-8

Procedure:

  1. Bring up network using x86 controller and check if all links are up.
  2. Disable auto-ignition.
  3. Bring down 1 or 2 links from the topology
  4. Remove the links brought down in step 3 using E2E API.
  5. Remove nodes forming the links which are down from the topology using E2E CLI.
  6. check if the E2E state machine is stable and nodes are deleted.
  7. Add nodes back to topology using API.
  8. Add the deleted links back to topology using API.
  9. Make the links alive by using API.
  10. Enable auto ignition.
  11. Verify the new nodes are now in topology and reporting to controller
  12. Run ping to verify connectivity.
APIs used:
/api/setLinkStatus
/api/setIgnitionState
/api/addLink
/api/delLink
/api/addNode
/api/delNode
/api/startPing

Pass/Fail Criteria:

  1. Verify that the E2E state machine is stable and nodes are deleted and added back.

PUMA_RF_E2E-11 Verify controller side config validation framework

Description: E2E Verify controller config tests to validate E2E will throw error if incorrect values are pushed for the nodes.

Test Setup: Fig-of-8

Procedure:

  1. Ignite network using x86 controller.
  2. Set forceGpsDisable to "x" for a node using TG CLI on the controller.
  3. Set OOB_INTERFACE to "nic3" for the network or particular node using TG CLI.
  4. Set laMaxMcs to 50 using TG CLI on controller.
  5. Check if all commands fail with error and config is not pushed to network.

APIs used:

/api/setNodeOverridesConfig
/api/getNodeOverridesConfig

Pass/Fail Criteria:

  1. Verify if the config is validated on the controller side and incorrect values are not pushed to the network.

PUMA_RF_E2E-12.2 Multiple node BGP POP config

Description: To test multiple BGP sessions to two different IP's on switch using different sites in a network.

Test Setup: Fig-of-8

Procedure:

  1. Configure multiple BGP sessions from 2 different switches to both the POP sites.
  2. Ignite the network and validate both POP are up.
  3. Disconnect fiber cable from one POP (manually? / port down?).
  4. Run pings from both the POP nodes.
  5. While ping is running, cut POP and check for ping latency.

APIs used:

/api/getNodeConfig
/api/setNodeOverridesConfig
/api/getNodeOverridesConfig

Pass/Fail Criteria:

  1. All pings go through and there is no loss of connectivity while failing POP or connectivity to router.
  2. Ping latency (need to confirm numbers)

PUMA_RF_E2E-12.1 Network ignition with 2 POP sites with BGP

Test Setup: Fig-of-8

Procedure:

  1. Configure 2 sites on fig-8 as POP nodes with BGP configured to the same peer
  2. Ignite the network and validate both POP nodes and whole network is up
  3. Validate BGP sessions are established on both POP nodes and default route is advertized
  4. Ping all nodes from POP sites to validate connectivity

Pass/Fail Criteria:

  1. Network Ignites successfully
  2. Both POP nodes are online, with BGP established and advertising default
  3. All pings go through

PUMA_RF_E2E-13.1 High Availability test - network interface Down on primary E2E

Description: This test checks high availability feature of E2E on a standard figure of 8 topology (with two E2E controllers on a network).

Test Setup: Fig-of-8

Procedure:

  1. Ignite the network using primary x86 controller with all the necessary controller configs on primary and secondary.
  2. Check network state to verify if all links are enabled and nodes are reachable (recheck network state).
  3. In parallel:
    1. Take down primary controller network interface for 300 sec (but do not shut down the controller).
    2. Ping between nodes.
  4. Ping all nodes from primary controller.
  5. Check state. (/api/getHighAvailabilityState)

Pass/Fail Criteria:

  1. All paths are up and operational after restoration of connection to E2E and ping between all nodes/Paths should have 0% packet loss.
  2. when primary controller is down the backup should be in 'active' state and network should remain up
  3. when primary is restarted, it should go back to 'active' state and backup should go back to 'passive' state
  4. All links and nodes in network should remain online

PUMA_RF_E2E-13.2 High Availability test - reboot primary E2E

Description: This test checks high availability feature of E2E on a standard figure of 8 topology (with two E2E controllers on a network).

Test Setup: Fig-of-8

Procedure:

  1. Ignite the network using primary x86 controller with all the necessary controller configs on primary and secondary.
  2. Check network state to verify if all links are enabled and nodes are reachable (recheck network state).
  3. In parallel:
    1. Reboot the primary E2E
    2. Ping between nodes.
  4. Ping all nodes from primary controller.
  5. Check state. (/api/getHighAvailabilityState)

Pass/Fail Criteria:

  1. All paths are up and operational after restoration of connection to E2E and ping between all nodes/Paths should have 0% packet loss.
  2. when primary controller is down the backup should be in 'active' state and network should remain up
  3. when primary is restarted, it should go back to 'active' state and backup should go back to 'passive' state
  4. All links and nodes in network should remain online

PUMA_RF_E2E-14 Controller switch after topology change, changes reflect in passive controller

Description: This test checks high availability feature of E2E on a standard figure of 8 topology (with two E2E controllers on a network).

Test Setup: Fig-of-8

Procedure:

  1. Ignite the network using primary x86 controller with all the necessary controller configs on primary and secondary.
  2. Check network state to verify if all links are enabled and nodes are reachable (recheck network state).
  3. Ping all nodes from primary controller
  4. Remove some links and nodes in the topology file.
    1. Backup original topology file to later restore
  5. Confirm change propagated back to secondary
  6. Give outage to primary for 300s and restore original topology on primary
  7. Ping all nodes from secondary controller - during 300s outage - Ensure its the same as step 5 missing the changes made
  8. After primary comes up ensure another ping check matches step 5

Pass/Fail Criteria:

  1. All paths are up and operational after restoration of connection to E2E
  2. Ping between all nodes/Paths should have 0% packet loss
  3. At the end of step 6, passive controller topology should not include the nodes and links removed.
  4. At the end of step 8, passive controller topology should show the nodes and links added.
  5. Ping between all nodes/Paths should have 0% packet loss

Description: To verify there are no link re-ignition attempts when the network is stable.

Test Setup: Fig-of-8

Procedure:

  1. Bring up TG network using E2E controller on x86 machine.
  2. Recheck network state.
  3. Ping for 3660 seconds on all terra interface for all links.
  4. Recheck network state.

Pass/Fail Criteria:

  1. All pings should go through with 0% packet loss.
  2. LinkupAttempts in the topology should not increment.

PUMA_RF_E2E-17 Change channel, MCS, txpower, Disable GPS of entire network

Description: Validate if network remains in a stable state if channel, MCS, TxPower is changed and all nodes are up. Also, check if network remains in a stable state if GPS is disabled in-band using config manager.

Test Setup: Fig-of-8(RF)

Procedure:

  1. Bring up the F8-CN network using the E2E controller with managed config enabled
  2. Change channel to 3.
    1. tg fw network channel_config --channel # (# = 1, 3, & 4)
    2. /api/setNodeOverridesConfig
  3. Check if network remains up after config change (expected action is 'set fw params when changed' when config is changed so links and node should stay up after config change)
  4. Check fw params to see if channel is updated
  5. Change channel back to 2.
  6. Check if network remains up after config change (expected action is 'set fw params when changed')
  7. Check fw params to see if channel is updated
  8. Change MCS to 3/5/7/9/10/12 on all nodes using E2E API
  9. Check if network remains up after config change (expected action is 'set fw params when changed')
  10. Check fw params to see if channel is updated
  11. Change MCS back to 12.
  12. Check if network remains up after config change (expected action is 'set fw params when changed')
  13. Check fw params to see if channel is updated
  14. Change TxPower to 12/17/21 on different nodes using using E2E API.
  15. Check if network remains up after config change (expected action is 'set fw params when changed')
  16. Check fw params to see if channel is updated
  17. Change TxPower back to 21.
  18. Check if network remains up after config change (expected action is 'set fw params when changed')
  19. Check fw params to see if channel is updated
  20. Disable GPS for whole network using E2E API (timeout: 300 sec)
  21. Check if network remains up after config change (expected action is 'set fw params when changed')
  22. Check if GPS is disabled in all nodes in firmware
  23. Enable GPS back in all nodes.
  24. Check if network remains up after config change (expected action is 'set fw params when changed')

Pass/Fail Criteria:

  • Verify channel is changed for whole network and all nodes/link are online on new channel using TG CLI after step 5.
  • MCS is changed for whole network and all nodes/link are online. Nodes and links should not flap while MCS is changed (after step 9)
  • TxPower is changed for whole network and all nodes/link are online (after step 11). Nodes and links should not flap while Tx power is changed.
  • Network remains up with GPS disabled on all nodes.(after step 15)

Description: To verify that E2E controller is able to ignite the P2MP setup even when some nodes and links are down.

Test Setup: P2MP

Procedure:

  1. Bring up TG network(P2MP setup) using E2E controller on x86 machine.
  2. Recheck network state.
  3. Stop minion on CN0, CN1, CN2 and CN3.
  4. Recheck network state should show the CN0,CN1, CN2 and CN3 nodes as offline and links associated with them as false.
  5. Give a delay of 60 seconds.
  6. Start minion on CN0 and CN1.
  7. Recheck network state should show the CN2 and CN3 nodes as offline and links associated with them as false while other links(CN0 and CN1) should be ignited.
  8. Stop minion service on CN0 and CN1.
  9. Start minion on CN2 and CN3.
  10. Give a delay of 60 seconds and check network state
  11. Recheck network state should show the CN0 and CN1 nodes as offline and links associated with them as false. CN2 and CN3 should show as ONLINE and links associated with them as true.
  12. Start minion on CN0 and CN1.
  13. Network should come up with all nodes after a delay of 60 seconds.

Pass/Fail Criteria:

  1. Recheck network state after step 13 should have all the nodes as online and all links as true.

Neighbor Discovery Tests

PUMA_RF_E2E-19 Topology Scan tests

Description: This test performs a topology scan at a given node, returning information about nearby nodes in a P2MP setup.

Test Setup: RF P2MP

Procedure:

  1. Start the E2E controller service in E2E controller
  2. Set the auto ignition to be disabled.
  3. Shut down the DN --> CN1 and DN—CN2 links down (tg link down)
  4. Initiate a Topology Scan (2 times) from DN using API service (txNode: DN) using /api/startTopologyScan.

Pass/Fail Criteria:

  • The output of the API call must have the details of all the CN1 and CN2(whose links are down) as responders address in the network. It must have 2 outputs with all the CN's details.
  • Check in the output of API for the CN1 and CN2 MAC address

Description: This test performs a link discovery scan at a given node, returning information about the best link(s) for a node.

Test Setup: RF P2MP

Procedure:

  1. Start the E2E controller service in E2E controller
  2. Set the auto ignition to be disabled. (Make sure the DNs and CN0 link is not alive with tg link down)
  3. Initiate a Topology Scan from CN using API service (targetMac: CN0) using /api/startLinkDiscoveryScan.
  4. Use API call to get the results of the scan status. (/api/getLinkDiscoveryScanStatus)

Pass/Fail Criteria:

  • At the end of step 3, "Link discovery scans started' message must be received.
  • The output of the API call after step 4 must have the MAC address of DN which have link in the topology file.

PUMA_RF_E2E-21 Redundancy-DN goes down

Description: P2P test between DN-P and CN where DN-P goes down and CN connects to the backup DN-B

Test Setup: Fig-of-8

Procedure:

  • Initialize the topology with the backup link DN-B ↔ CN and add is_backup_cn_link = true
  • Bring up the link Between DN-P ↔ CN using E2E
  • Power down DN-P using PDU (don't bring it up)
  • Controller should bring up the link between DN-B ↔ CN (Only if DN-P has been down for over 5 mins as linkup_backup_cn_link_interval default value is 5 mins)
    • Run test with different interval values: 30 sec, 1 min, 3 min and default value (5 min)

Passing:

  • E2E controller will ignite the DN-B ↔ CN link after DN-P goes down

PUMA_RF_E2E-22 Redundancy-DN goes down

Description: P2P test between DN-P and CN where DN-P ↔ CN goes down DN-P turns off and CN connects to the backup DN-B

Test Setup: Fig-of-8

Procedure:

  • Initialize the topology with the backup link DN-B ↔ CN and add is_backup_cn_link = true
  • Bring up the link Between DN-P ↔ CN using E2E
  • Bring down the link between DN-P ↔ CN and then power off DN-P using PDU
  • Controller should bring up the link between DN-B ↔ CN (Only if DN-P has been down for over 5 mins as linkup_backup_cn_link_interval default value is 5 mins)
    • Run test with different interval values: 30 sec, 1 min, 3 min and default value (5 min)

Passing:

  • E2E controller will ignite the DN-B ↔ CN link after DN-P goes down

PUMA_RF_E2E-23 Redundancy-CN goes down

Description: P2P test between DN and CN where CN goes down and comes back up and it connects back to DN-P

Procedure:

  • Initialize the topology with the backup link DN-B ↔ CN and add is_backup_cn_link = true
  • Bring up the link Between DN-P ↔ CN using E2E
  • Reboot CN
  • Controller brings up the link between DN-P ↔ CN

Passing:

  • E2E controller will ignite the DN-P ↔ CN link after CN reboots

PUMA_RF_E2E-24 Redundancy-CN goes down

Description: P2P test between DN and CN where CN goes down for over 5 mins and comes back up and it connects back to either DN-P or DN-B

Procedure:

  • Initialize the topology with the backup link DN-B ↔ CN and add is_backup_cn_link = true
  • Bring up the link Between DN-P ↔ CN using E2E
  • Power down CN for over 5 mins(using PDU) and power it on
  • Controller brings up the link between DN-P ↔ CN or DN-B ↔ CN

Passing:

  • E2E controller will ignite either DN-P ↔ CN or DN-B ↔ CN after CN powers on.